PLANNING
GUIDE
7.1
Specications subject to change without notice. Phone: (800) 793-0093www.dacor.com
36” (91.4 cm) - 42” (106.7 cm)
48” (121.9 cm) - 54” 137.2 cm)
30”
(76.2 cm)
15 ¾” (40.0 cm)
Chimney
12 9/16” (31.9 cm)
12 ½”
(31.8 cm)
15 ½”
(39.4 cm)*
28” (71.1 cm) to 36” (91.4 cm)
DHI SERIES OVERALL DIMENSIONS
Blower
600 CFM* (1200 CFM* for units with 2 blowers)
with electronic speed control
Blower Speeds 4
Lights 12 Vac, 20 Watt halogen
Filters Bafe type, dishwasher safe
Exhaust 8 Inch
Finish 430 stainless steel
Total connected
load
120 Vac, 60 Hz (see table at right for current rating)
Circuit
requirements
120 Vac, 15 Amp. grounded, dedicated 3-wire
circuit (hot, neutral, ground)
* At zero inches static pressure
** IMPORTANT ORDERING INFORMATION: Each model
requires that you order a chimney assembly (Part number
DHICH) in addition to the hood assembly part number.
Discovery
36”, 42”, 48” and 54” Wide
Ceiling Mount Island Hoods
DHI
Model** Blowers Lights Filters
Maximum Current
Draw
DHI361 1 4 1 3.8 Amp.
DHI421 1 4 1 3.8 Amp.
DHI482 2 4 2 6.8 Amp.
DHI542 2 6 2 7.1 Amp.
GENERAL SPECIFICATIONS
MODEL SPECIFIC SPECIFICATIONS
* 18” 1/4 on models DHI482 and DHI542
Chimney can accommodate up to 10” round duct work
All tolerances: ±1/16” (±1.6 mm), -0, unless otherwise stated
WARNING
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the
accompanying installation instructions.
DO NOT install an additional in-line or external blower to
increase the length of the duct run. Even small differences
between blower air flow rates can greatly reduce the air draw
of the hood.
Document # PG07-002
Revised 10/02/11 Page 1/1
Maximum Duct Length
The maximum straight duct length for the hood is 50 feet. To determine the
actual maximum duct run, subtract the equivalent length of each elbow,
transition and cap from 50 feet. See the Duct Planning Guide or the
installation instructions for more details.
IMPORTANT: The minimum installed distance from the hood to the cooking
surface must be no less than 30 inches. The minimum specified distance
may be higher for the particular range or cooktop in use. Check the
manufacturers specifications for the cooktop or range.