Technical Diagnostic Quick Reference Guide Technical Assistance Line 800-353-2267
Dacor Discovery Oven Diagnostic Mode: Models: EO, PO, MOV, MOH, SINGLES AND DOUBLES, 27” A
Error Code: Description of Failure: Page: Error Code: Description of Failure: Page:U20 OVER TEMP (UPPER/SINGLE) Cook temp over 610F for 2 min 9-34 U43
Dacor Discovery Range Quick Set Guide Range Models: ER30D, ER30DSR, ER36D & ER48D Control Panel Position: The Cont
Dacor Discovery Range Fault Code Troubleshooting Guide Models: ER30D, ER30DSR, ER36D and ER48D General Error Codes The following codes give a gene
Dacor Discovery Duel-Fuel Range ERC Diagnostic Test Models: ER30D, ER30DSR, ER36D, ER48D and ER60D To access the ERC Diagnostic Test: Turn circuit
Test 16: Convection Fan right/large oven side Press the right/large oven side PURE CONV. Key and verify that the CONV. And ON icons are lit. Verify t
RequirementPress each number key. The number will be displayed on the control display.Press the BAKE key. Verify bake element is on, measure amperage
Error Code Error Condition Software Logic Description C01 Shorted Key Failure Release of Key not seen in 2 mionutes. Membrane Shorted Key FailureC23OC
Renaissance Induction Range - Induction Generator Technical Features Renaissance Induction Range Models: RR30NS, RR30NIS, RR30NFS & RR30NIF
Dacor Technical Assistance: 800-353-2267 Renaissance Induction Range – Cooktop Error Codes Models: RR30NS, RR30NIS, RR30NFS & RR30NIFS Erro
Dacor Contact Information: Dacor Customer Service: 800-793-0093 X 2813 [email protected] Dacor Distinctive Service: 800-793-0093
Dishwasher Factory Test Mode 24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S & MDH24S 30” Models: ID30, ED30S
Dishwasher Fault Codes: 24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S & MDH24S Fault Cause Effect Sol
Dishwasher Diagnostic Quick Reference Sheet. S1 L1 L2 L3 L4 L5 L6
Dishwasher Control Programming and Fault Code Reference Sheet Control Programming DDWF24S When the power is switched on for the first time after rep
Programming Mode: Note: The Programming Code is located on the Serial Plate. 1. Press and Hold the “Door Alarm” Keypad. 2. Press and hold the
Service Test 121 – Open Damper Test Press the Refrigerator Up Keypad and Down Keypad to toggle Damper (OP) open and (CL) Closed. Note: If Damper is op
Programming Mode: NOTE: The Program Code is located on the Serial Plate after the word Code. 1. Press and hold the WATER Keypad. 2. Press and h
Service Test - 151 Fresh Food Door State • Will show state of Fresh Food Door. OP (open) CL (closed). NOTE: By pushing either fresh food door switches
Service Test Mode There are several test modes available through the diagnostic system. Use of these test modes can greatly decrease the
Thermistor Tests: This test will give a “GO – NO GO” test of all thermistors. Pressing the Power Interrupt Button will report the condition of the
Technical Diagnostic Quick Reference Index Dacor Contact information - Page: 2 Index - Page: 3 & 4 Serial Number Format – Page: 5 Oven Tempera
Service Test 17 – Compressor Minimum Speed The compressor should have been off for at least five minutes prior to this test. If the off time is no
Service Test 28 – Actuator Switch This test displays the current state of the dispenser actuator (paddle switch) as read by the Main Control board
Diagnostic Test Mode There are several test modes available through the diagnostic system. Use of these test modes can greatly decrease
Service Diagnostic Mode Chart Water Filter Input (WFI) Test To confirm that the water valves are being monitored by the WFI control, follow the pr
Dacor WineStation Screen Functions Model: DYWS4 The WineStation is designed to provide a wide range of operating functions. Below you will find an
Dacor WineStation Screen Functions Continued… Model: DYWS4 3. Setting Pour Volumes. a. Next you will select “Set VOL”. b. Volume sizes will appear
Accessing the Main Programming Menu: Remove the drip tray. Unlock the front panel door. When the door is open, the buttons on the front of th
Turning Pre-brew On and Off: 1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Pre-brew” appears on the display
Technical Diagnostic Quick Reference Index Continued… Distinctive Wall Oven & Range Diagnostic Mode - Page: 16 Wall Oven Models: DO130, DO230 R
Dacor Serial Number Format: **Prior to the 38th week of 2002 the serial number format was: FC2371234 In 2002 Dacor changed the serial number format sl
Dacor Technical Assistance: 800-353-2267 Oven Temperature Calibration Instructions: Classic Wall Oven & Range Temperature Calibration Proc
Dacor Technical Assistance: 800-353-2267 Oven Temperature Calibration Instructions Continued: Discovery Dual Fuel Range Temperature Calibration P
To access the ERC Quick Test Program: Turn circuit breaker off or disconnect power to unit, count to five and then turn power back on. Make su
-F0- Shorted Or Jammed Input Device This failure will appear if a shorted or jammed input device is defective. Possible causes include shorted