Dacor MCS/D Troubleshooting Guide

Browse online or download Troubleshooting Guide for Small kitchen appliances Dacor MCS/D. Dacor MCS/D Troubleshooting guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Quick Reference Guide

Technical Diagnostic Quick Reference Guide Technical Assistance Line 800-353-2267

Page 2 - Dacor Contact Information:

Dacor Discovery Oven Diagnostic Mode: Models: EO, PO, MOV, MOH, SINGLES AND DOUBLES, 27” A

Page 3

Error Code: Description of Failure: Page: Error Code: Description of Failure: Page:U20 OVER TEMP (UPPER/SINGLE) Cook temp over 610F for 2 min 9-34 U43

Page 4 - (bottom of page)

Dacor Discovery Range Quick Set Guide Range Models: ER30D, ER30DSR, ER36D & ER48D Control Panel Position: The Cont

Page 5

Dacor Discovery Range Fault Code Troubleshooting Guide Models: ER30D, ER30DSR, ER36D and ER48D General Error Codes The following codes give a gene

Page 6

Dacor Discovery Duel-Fuel Range ERC Diagnostic Test Models: ER30D, ER30DSR, ER36D, ER48D and ER60D To access the ERC Diagnostic Test: Turn circuit

Page 7

Test 16: Convection Fan right/large oven side Press the right/large oven side PURE CONV. Key and verify that the CONV. And ON icons are lit. Verify t

Page 8

RequirementPress each number key. The number will be displayed on the control display.Press the BAKE key. Verify bake element is on, measure amperage

Page 9

Error Code Error Condition Software Logic Description C01 Shorted Key Failure Release of Key not seen in 2 mionutes. Membrane Shorted Key FailureC23OC

Page 10 - Dacor Tec-Line: 800-353-2267

Renaissance Induction Range - Induction Generator Technical Features Renaissance Induction Range Models: RR30NS, RR30NIS, RR30NFS & RR30NIF

Page 11

Dacor Technical Assistance: 800-353-2267 Renaissance Induction Range – Cooktop Error Codes Models: RR30NS, RR30NIS, RR30NFS & RR30NIFS  Erro

Page 12

Dacor Contact Information: Dacor Customer Service: 800-793-0093 X 2813 [email protected] Dacor Distinctive Service: 800-793-0093

Page 13

Dishwasher Factory Test Mode 24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S & MDH24S 30” Models: ID30, ED30S

Page 14 - Tec-Line: 800-353-2267

Dishwasher Fault Codes: 24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S & MDH24S Fault Cause Effect Sol

Page 15

Dishwasher Diagnostic Quick Reference Sheet. S1 L1 L2 L3 L4 L5 L6

Page 16 - Lower Oven Test

Dishwasher Control Programming and Fault Code Reference Sheet Control Programming DDWF24S When the power is switched on for the first time after rep

Page 17

Programming Mode: Note: The Programming Code is located on the Serial Plate. 1. Press and Hold the “Door Alarm” Keypad. 2. Press and hold the

Page 18

Service Test 121 – Open Damper Test Press the Refrigerator Up Keypad and Down Keypad to toggle Damper (OP) open and (CL) Closed. Note: If Damper is op

Page 19

Programming Mode: NOTE: The Program Code is located on the Serial Plate after the word Code. 1. Press and hold the WATER Keypad. 2. Press and h

Page 20

Service Test - 151 Fresh Food Door State • Will show state of Fresh Food Door. OP (open) CL (closed). NOTE: By pushing either fresh food door switches

Page 21 - Dishwasher Fault Codes:

Service Test Mode There are several test modes available through the diagnostic system. Use of these test modes can greatly decrease the

Page 22

Thermistor Tests: This test will give a “GO – NO GO” test of all thermistors. Pressing the Power Interrupt Button will report the condition of the

Page 23 - Control Programming DDWF24S

Technical Diagnostic Quick Reference Index Dacor Contact information - Page: 2 Index - Page: 3 & 4 Serial Number Format – Page: 5 Oven Tempera

Page 24

Service Test 17 – Compressor Minimum Speed The compressor should have been off for at least five minutes prior to this test. If the off time is no

Page 25

Service Test 28 – Actuator Switch This test displays the current state of the dispenser actuator (paddle switch) as read by the Main Control board

Page 26 - Control Panel Touch Pads

Diagnostic Test Mode There are several test modes available through the diagnostic system. Use of these test modes can greatly decrease

Page 27

Service Diagnostic Mode Chart Water Filter Input (WFI) Test To confirm that the water valves are being monitored by the WFI control, follow the pr

Page 28 - Service Test Mode

Dacor WineStation Screen Functions Model: DYWS4 The WineStation is designed to provide a wide range of operating functions. Below you will find an

Page 29

Dacor WineStation Screen Functions Continued… Model: DYWS4 3. Setting Pour Volumes. a. Next you will select “Set VOL”. b. Volume sizes will appear

Page 30

Accessing the Main Programming Menu: Remove the drip tray. Unlock the front panel door. When the door is open, the buttons on the front of th

Page 31 - FoodSaver™ TEST MODE

Turning Pre-brew On and Off: 1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Pre-brew” appears on the display

Page 32

Technical Diagnostic Quick Reference Index Continued… Distinctive Wall Oven & Range Diagnostic Mode - Page: 16 Wall Oven Models: DO130, DO230 R

Page 33

Dacor Serial Number Format: **Prior to the 38th week of 2002 the serial number format was: FC2371234 In 2002 Dacor changed the serial number format sl

Page 34

Dacor Technical Assistance: 800-353-2267 Oven Temperature Calibration Instructions: Classic Wall Oven & Range Temperature Calibration Proc

Page 35 - Continued…

Dacor Technical Assistance: 800-353-2267 Oven Temperature Calibration Instructions Continued: Discovery Dual Fuel Range Temperature Calibration P

Page 36

To access the ERC Quick Test Program: Turn circuit breaker off or disconnect power to unit, count to five and then turn power back on. Make su

Page 37

-F0- Shorted Or Jammed Input Device This failure will appear if a shorted or jammed input device is defective. Possible causes include shorted

Comments to this Manuals

No comments