Dacor ILHSF8 Installation Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
7
Technical Data
Blower Ratings
Wiring Diagram
Model
Number
Nominal
Rating*
Actual
Rating*
ILHSF8 600 CFM 650.7 CFM
ILHSF10 1100 CFM 1115.9 CFM
* At zero inches static pressure
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
200 400 600 800 1000 1200
ILHSF10 Blower Performance
Airflow CFM (Cubic feet/minute)
Static pressure - inches of water
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
200400 600800
ILHSF8 Blower Performance
Permanent
PSC “Type E” Motor
Split Capacitor
Motor
Yellow/Green
Blue Blue
Terminal
block
Green/Yellow
GND
N1
L1
BrownBrown
BlueBlack
Black
Motor
Run
Capacitor
Page view 8