PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
CI.14
Stiffener
Cabinet face
Countertop
Floor
3/8” Min. (10 mm) space
behind raised vent
chassis to clear stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
SGM Series Cooktop
RGC/SGM Series Drop-In Gas Cooktop
with ERV/PRV Series Raised Vent
COMBINATION INSTALLATIONS
Document # PGCI-008 Revised 05/07/09 Page 1/2
WARNING
Observe all governing codes and ordinances during ◊
planning and installation. Contact your local building
department for further information.
All appliances must be installed in accordance with the ◊
accompanying installation instructions.
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted
Cutout Dimensions
Side View - RGC/SGM Series Cooktop with
ERV/PRV Series Raised Vent
IMPORTANT: Be careful to use the correct cutout diagram (on page 2/2) to determine the countertop dimensions. Carefully double check
all dimensions against the table below and the correct diagram before cutting the countertop.
* Total cutout depth, accommodates both the cooktop and raised vent
** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D).
RGC or SGM series cooktop
Countertop Dimensions
Installation Type Cutout
Diagram
C (minimum) D E F G H
RGC/SGM304 with
ERV30 or PRV30
Figure 1
(Square)
3/8”
(10 mm)
22 1/2” *
(572 mm)
27 3/4”
(686 mm)
NA NA NA
RGC/SGM365 with
ERV36 or PRV36
Figure 1
(Square)
3/8”
(10 mm)
22 1/2” *
(572 mm)
33 5/8”
(854 mm)
NA NA NA
RGC/SGM466 with
PRV46
Figure 2
(Notched)
3/8”
(10 mm)
22 1/2” *
(572 mm)
44 3/4”
(1137 mm)
43 1/2”
(1105 mm)
5/8”
(16 mm)
2 5/8” **
(67 mm)