Dacor EWD27 Operations Instructions Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
Pushinontab
Slide mounting bracket
under clip on slide
Clip on slide
Pull up on T
drawer front
/
Slide
Push drawer front
down until tab locks
in place
Drawer Removal Drawer Installation
....
Problem Solution Guide
::_J_ PROBLEM MAYBE CAUSEDBY WHAT TO DO
Nothing works.
Drawer does not slide smoothly
or drags.
Excessive condensation,
One or more of the indicator
lights on the control panel blink
on and off (one second on, one
second off).
Power plug disconnected.
Timer is not set.
Warming drawer is not connected
to power.
Tripped circuit breaker or blown
fuse.
Ambient temperature below 32°F
(ooc).
Drawer is incorrectly mounted into
slide mechanism.
Drawer is over-loaded or the load
is unbalanced.
Warming drawer not preheated.
Incorrect humidity control setting.
The control panel computer has
detected an error:
#1 - Temperature error
#2 - Sensor error
#3 - Key pad error
#4 - Control error
Connect plug to a dedicated, grounded, three-
prong electrical outlet.
Select time duration according to the
Operating Znstructions section.
Plug the warming drawer into a 120 Vac,
15 Amp., dedicated electrical outlet.
Check the circuit breaker panel or fuse box
tripped breaker or blown fuse.
Temperature around warming drawer must be
above freezing.
Remount drawer into slide, per instructions
above
Reduce the weight to less than 50 pounds.
Redistribute drawer contents
Preheat the warming drawer before each use
Set humidity control to CRISP to allow mois-
ture to vent
Try resetting the computer. Disconnect the
power cord, wait 20 seconds, then reconnect
it. Check the control panel. If the indicator
light still flashes, call for service. See page 8
7
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals