Installation instructions
3-Wire Cable from Home Power Supply - U.S. Only
IMPORTANT: Use the 3-wire cable from home power supply where local codes permit a
3-wire connection.
A
E
B
G
H
I
C
D
F
A. Cable from home power supply
B. Junction box
C. Black wires (normally L1)
D. White wires (normally N-neutral)
E. green wires (normally G-ground)
F. 4-wire flexible conduit from oven
G. Red wires (normally L2)
H. UL listed wire connectors
I. UL listed or CSA approved conduit
connector
1. Connect the 2 black wires (C) with a
UL-listed wire connector.
2. Connect the 2 white wires (D) and the
oven's green (bare) ground wire with
a UL-listed wire connector.
3. Connect the 2 red wires (G) with a
UL-listed wire connector.
4. Attach the junction-box cover.