Dishwasher Fault Codes:
24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S &
MDH24S
Fault Cause Effect Solution
F-1 Pressure Switch is in the
closed position after two full
drain procedures.
Three long beeps. F1 will be displayed
only during the Diagnostic mode.
Press Cancel key twice to reset this
fault. Replace Pressure Switch.
F2 Inlet Valve does not close. Three long beeps. F2 will be displayed
to the user and in Diagnostic mode.
Drain pump is ON until open door.
Press Cancel key twice to reset this
fault Replace Inlet Valve. Replace
control board.
F3 Low inlet water pressure. Three long beeps. F3 will be displayed
to the user and in Diagnostic mode.
Press Cancel key twice to reset this
fault. Ensure that Inlet hose is ON.
Replace Flow Meter. Replace Inlet
Valve.
F4 No response signal from the
WPS.
Wash cycle will go into a de-fault time
table soil 3 & temp 0. F4 will be
displayed only during the Diagnostic
mode.
Check WPS connection Replace
WPS.
F9 Heater failure Temperature does not in-crease. Wash
cycle will go into a default time table for
Heater ON time. F9 will be displayed
only during the diagnostic mode.
Replace heater. Replace WPS.
Replace Control board.
30” Models: ID30, ED30SCH, ED30SCP, ED30SBK & ED30SBR
Fault Cause Effect Solution
F-1 Pressure Switch is in the
closed position after two full
drain procedures.
Three long beeps. F1 will be displayed
only during the Diagnostic mode.
Press Cancel key twice to reset this
fault. Replace Pres-sure Switch.
F2 Inlet Valve does not close. Three long beeps. F2 will be displayed
to the user and in Diagnostic mode.
Drain pump is ON until open door.
Press Cancel key twice to reset this
fault Replace Inlet Valve. Replace
control board.
F3 Controller failure to
communicate with the Power
Board
Fault will be visible in the first three
seconds of initial power-up. “F3” will
flash on the display. Dishwasher will be
disabled
Check control and power board
compatibility and the wire harness
between the two. Replacement of the
control and power boards will be
necessary if problem persists.
F4 No response signal from the
WPS.
Wash cycle will go into a de-fault time
table soil 3 & temp 0. F4 will be
displayed only during the Diagnostic
mode.
Check WPS connection Replace
WPS.
F9 Heater failure Temperature does not in-crease. Wash
cycle will go into a default time table for
Heater ON time. F9 will be displayed
only during the diagnostic mode.
Replace heater. Replace WPS.
Replace Control board.
24” Millennia Models: MDW24S & EDW24S
Display Codes (Readout)
LO Low Liquid in the Rinse Aid Dispenser CL Close and latch the door
PF A Power Failure has occurred 01-04 Hours delay before the dishwasher will start
HO Water Heating Delay CF Clean Filters