Electrical Connection
WARNING
Do not install the dishwasher unless the electrical
service provided meets the dishwasher specifications
(see page 4).
To avoid an electrical shock hazard, turn off power to
the junction box at the circuit breaker panel or fuse
box before proceeding.
Do not cross the drain, water and electrical lines in
front of the dishwasher motor or frame.
Connect the dishwasher ground wire to a separate,
properly grounded wire installed by a licensed
electrician.
o A grounded cold water pipe must have metal
continuity to an electrical ground and must not be
interrupted by insulating materials. Any insulating
materials must be jumped with a length of No. 4
copper wire securely damped to bare metal at both
ends. See diagram below.
Joining aluminum building wire to stranded copper
wire should be done by a qualified electrician using
materials recognized by UL and local codes.
1. Make sure power to the house junction box is off.
2. Cut an access hole for the wiring in the shaded area
shown in the cabinet diagram below.
---kl
Safe area for
O routing electrical
wirinc
Electrical wiring
©
Cut access hole
"_ 6"XX_-__"_X{1 1/2"
,
,
Feed the electric wire through the access hole. Pull
out all of the slack. Route the electrical cable into the
installation area shown above. Failure to route the
wiring as shown may result in damage during final
installation.
Strip and connect the other end of the wiring to the
house junction box using one of the methods shown
below.
To house circuit breaker
panel or fuse box
Wire nut,
3 pla_,
Strain relief \
Junction box
To dishwasher
Standard 3-Wire Connection
to House Junction Box
To house circuit breaker
panel or fuse box
Junction box
GREEN
Strain relief
To dishwasher ,'_'
3-Wire Connection
with External Ground
Separate No. 10 (minimum)
copper ground wire
"Wire nut,
3 places
No. 4
copper wire
Meter
ps
-- Bare metal
Insulated Pipe Jumper
(if necessary)