Dacor DOB30M977SS Installation Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
English24
Installation requirements
Installation requirements
Flexible conduit from the oven should be connected directly to the junction box and
both sides of the line fused.
Do not cut the conduit. The oven should be removable for service without
disconnecting th
e conduit.
A UL-listed or CSA-approved conduit connector is required.
If the house has aluminum wiring:
1. Connect a section of solid copper wire to the ends of the flexible conduit leads.
2. Connect the aluminum wiring to the added section of copper wire using special
connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommendations. Aluminum/copper
connection must conform with local codes and industry-accepted wiring practices.
Power requirements for models DOB30M977D*, and DOB30M977S*, appear in this table:
Model
240 VAC 208 VAC
kW kW
DOB30M977D* 11.2 8.4
DOB30M977S* 5.6 4.2
Page view 23