English24
Installation requirements
Installation requirements
• Flexible conduit from the oven should be connected directly to the junction box and
both sides of the line fused.
• Do not cut the conduit. The oven should be removable for service without
disconnecting th
e conduit.
• A UL-listed or CSA-approved conduit connector is required.
• If the house has aluminum wiring:
1. Connect a section of solid copper wire to the ends of the flexible conduit leads.
2. Connect the aluminum wiring to the added section of copper wire using special
connectors and/or tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommendations. Aluminum/copper
connection must conform with local codes and industry-accepted wiring practices.
Power requirements for models DOB30M977D*, and DOB30M977S*, appear in this table:
Model
240 VAC 208 VAC
kW kW
DOB30M977D* 11.2 8.4
DOB30M977S* 5.6 4.2