Power Pack
IVS1, IVS2, IVSR1, IVSR2
L65338 rev B
7.5
21 1/4"
(540mm)
22 5/8"
(575mm)
6"
(152mm)
11 1/16"
(281mm)
12 1/4"
(311mm)
Electrical
Access
8" (203mm) Round x 2" (51mm) High
with back draft damper
Mounting
Holes
(typ. all sides)
IVS/R1 OVERALL DIMENSIONS
(Isometric View)
33 1/4"
(845mm)
34 1/2"
(876mm)
6"
(152mm)
11 1/16"
(281mm)
12 1/4"
(311mm)
Electrical
Access
8" (203mm) Round x 2" (51mm) High
with back draft damper
Mounting
Holes
(typ. all sides)
IVS/R2 OVERALL DIMENSIONS
(Isometric View)
21"
(533mm)
8"
(203mm)
12"
(305mm)
10" Round
Model No.
Dedicated Circuit
Required
Maximum
Duct Length
Total
Connected Load
Approximate
Shipping Weight
IVS1
120VAC, 60Hz, 15A
(Breaker)
Maximum 60
Equivalent
Straight Feet
1.4kW (12A)
25 lbs.
IVSR1 21 lbs.
IVS2 38 lbs.
IVSR2 29 lbs.
12 1/4"
(311mm)
Equal Equal
22 5/8" (575mm)
6 1/8"
(156mm)
8" Round collar
#
,
#
,
IVS/R1 OVERALL DIMENSIONS
(Top View)
12 1/4"
(311mm)
34 /12" (876mm)
6 1/8"
(156mm)
8" Round
Collars
Equal Equal
C
L
C
L
C
L
C
L
6 1/2"
(165mm)
6 1/2"
(165mm)
IVS/R2 OVERALL DIMENSIONS
(Top View)
ATD10 OVERALL DIMENSIONS
(Isometric View)
(For use with IVS/R2)
NOTES:
1. An Internal Blower is included with IVS1/IVS2
models. Blower Ratings: 1200CFM for IVS2 and
600CFM for IVS1.
2.
Remote Blower is required for IVSR1/IVSR2
models.
3.
The ATD10 is sold seperately.
1/1062805
Page view 0