Dacor Discovery MOV User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
PLANNING
GUIDE
1.6
Specications subject to change without notice. Phone: (800) 793-0093www.Dacor.com
27 and 30 Inch Wide, Single,
Discovery Wall Ovens
EO, MOH, MOV
NOTES:
1. 24” (61.0 cm) minimum interior cabinet depth. Back of
cabinet may need to be removed.
2. 3/4” (1.9 cm) support platform (flush with cutout).
CUTOUT DIMENSIONS
C
A
B
4“ typical toe kick (shown)
Alternate
electrical
location
3/4” (1.9 cm)
support platform
Recommended
electrical
location
31 1/4” (79.4 cm)
recommended
(may be altered)
1 ¾“ (4.5 cm) min.
clear to top of
door for heat
exhaust
1“ (2.5 cm)
min. clear to
bottom
of door
CUTOUT DIMENSIONS -
UNDER-COUNTER INSTALLATION
36” Typical
(91.4 cm)
1 1/2”
(3.8 cm)
typical counter
4“ typical toe kick (shown)
1“ (2.5 cm) min. to combustibles
A
B
3/4” (1.9 cm)
support platform
Recommended
electrical
location
1 ¾“ (4.5 cm) min.
to combustible floor
Model A B C
EO127
27 7/16”
(69.7 cm)
25 1/2”
(64.8 cm)
27”
(68.6 cm)
MOH127
MOV127
EO130
28 1/2”
(72.4 cm)
30”
(76.2 cm)
MOH130
MOV130
3. 1/8” (3 mm) minimum clearance from appliance to
adjacent cabinet doors/drawers.
4. Two (2) Single Ovens are not approved in a stack
configuration.
Alternate
electrical
locations
4“ (10.2 cm) min.
between cutout
Recommended electrical location
4“ typical toe kick (shown)
1“ (2.5 cm) min. to combustibles
A
B
3/4” (1.9 cm)
support platform
A
B
3/4” (1.9 cm)
support platform
36” Typical
(91.4 cm)
1 1/2”
(3.8 cm)
typical counter
1 ¾“ (4.5 cm) min.
to combustible floor
CUTOUT DIMENSIONS
SIDE-BY-SIDE UNDER-COUNTER INSTALLATION
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.
Document # PG01-001
Revised 01/25/11 Page 2/2
Page view 1