11
Installation Instructions
Three Wire Connection with External Ground
Conduit to
oven
Incoming
power
Wire nut,
4 places
Junction box
Separate 10 AWG
wire minimum
Clamp wire tightly
to pipe
RED
RED
WHITE
WHITE
GREEN
GREEN
BLACK
BLACK
Clamps
Bare metal
Insulating device
4 AWG wire
(minimum)
Insulated Pipe Jumper