Installation requirements
Connect directly to the circuit-breaker box (or fused disconnect) through the
flexible, armored or nonmetallic sheathed, copper cable with grounding wire. (See
Electrical connection.)
Flexible conduit from the oven should be connected directly to the junction box.
Fuse both sides of the line.
Do not cut the conduit. The conduit length lets the oven be pulled out for service.
A UL-listed or CSA-approved condui
t connector must be provided.
If the house has aluminum wiring:
– connect a section of solid copper wire to the ends of the flexible conduit leads.
– connect the aluminum wiring to the added section of copper wire using special
connectors/tools designed and UL-listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended procedure.
Aluminum/copper connection must comply with local codes and industry-accepted
wiring practices.
For power requirement for model DOC30M977D refer to the following table.
Model 240 VAC 208 VAC
DOC30M977D* 8.9 kW 6.7 kW