Installation instructions
4-Wire Cable from Home Power Supply
IMPORTANT:
Use the 4-wire cable from home power supply in the U.S. where local
codes do not allow grounding through neutral, New Branch circuit installations (1996
NEC), mobile homes and recreational vehicles, new construction, and in Canada.
A
E
B
G
H
I
C
D
F
A. Cable from home
power supply
B. Black wires (normally L1)
C. Red wires (normally L2)
D. 4-wire flexible conduit from oven
E. Junction box
F. White wires (normally N-neutral)
G. UL listed wire connectors
H. green wires (normally G-ground)
I. UL-listed or CSA-approved conduit
connector
1. Connect the 2 black wires (B) with a
UL-listed wire connector.
2. Connect the 2 red wires (C) with a UL-
listed wire connector.
3. Connect the 2 white wires (F) with a
UL-listed wire connector.
4. Connect the green (bare) ground wire
(H) from the oven cable to the green
(bare) ground wire in the junction box
with a UL-listed wire connector.
5. Install the junction-box cover.