Heater
The heater in this dishwasher is inline between the wash
motor and the delivery tube. The 1200W heater wraps around
a stainless steel core tube. The heater can only be energized,
during a wash cycle, while the wash pump is running after the
low level pressure switch has been activated. Water is heated
as it passes through the heater to the center spray arm. This
heater has internal thermal protection.
While checking the heater, do not apply power to
it until the tub has filled with water and the motor
is operating!
Temperature Sensor and Soil Sensor
The electronic control reads information from two sensors to
adjust the wash cycle. The Thermistor and soil sensor are
integrated into the same housing mounted to the right side of
the sump. Both sensors extend into the outer section of the
sump to perform independent tasks.
The electronic control uses the Thermistor to monitor the
temperature of the water in the dishwasher. The turbidity or
soil sensor is used to monitor soil levels during a wash cycle.
A small amount of DC power is sent to the soil sensor emitter
mounted in one of the posts of the sensor housing. This emitter
turns DC power into a small beam of light to be transmitted to a
detector in the other post. As this light passes from one post to
another, the amount of soil in the water partially blocks the light
seen by the detector. The detector changes this light back into
DC voltage which returns to the control for analysis.
The level of soil in the water can be determined by this
returned voltage. Based on this information, the control makes
adjustments to the remainder of the wash cycle.
Checking the Thermistor
Start a Normal wash cycle and allow the dishwasher to fill and
wash for two minutes at which time press the Start/Cancel pad
twice (2). This will stop the dishwasher and send it to idle.
With the dishwasher in idle, press and hold the Normal wash and
the Start/Cancel pads simultaneously to start the test. The test
will show a two digit display for the temperature of the water
(from 0°F to 99°F). If the water temperature is over 99°F a
decimal point will be displayed to show 100°F, then the added
degrees over. This reading will be updated every three seconds
until the Start/Cancel pad is depressed to stop the test.
Refer to Water Temperature Test Mode on page 3-2 to check
the temperature of the thermistor.
1.
2.
INLINE HEATER – FIGURE 14
SENSOR MOUNTED
INTO SUMP – FIGURE 15
Thermistor
SENSOR WITH SEAL
– FIGURE 16
Thermistor
Turbidity Sensor
Page view 13