seCTion 4 - serviCe & DisasseMbly
Blower Assembly
Remove dishwasher cabinet. See CABINET REMOVAL for detailed
instructions.
After cabinet is removed, set unit upright.
From inside of the tub, depress retaining clips. (See Figure 54)
Blower assembly is removed from top outside of tub.
Remove blower from side duct and remove wires from blower motor.
Reverse procedure to reinstall.
Sump
Disconnect dishwasher from power and water supplies.
Remove drain line.
Remove lower spray arm, filters, and volute cover from
inside of tub. Remove four screws mounting sump to tub.
Remove dishwasher from underneath countertop.
Lay dishwasher on its back on a protective pad.
Remove wires to sensor.
Remove hoses from sump. (pressure switches,
wash motor intake, lower spray arm)
The drain pump may be removed with the sump
for convenience.
Remove sump from tub. Then remove drain pump, sensor,
and sump gasket from sump. (If replacing the sump, these
parts may be installed on the new sump.)
Reassemble by mounting sump to tub and securing screws into
sump from inside tub. (This will hold the sump in place.)
Reinstall hoses and reposition hose clamps.
Reinstall wire plug to sensor.
Finish reassembly by installing cabinet and remaining parts inside tub.
Recheck sump mounting screws by filling dishwasher with water and assessing for leaks.